Pressure Tubing for CardioPerfect Workstation and CP200

Pressure Tubing for CardioPerfect Workstation and CP200

Welch Allyn

Diagnostic cardiology / respiratory equipment accessory
  • Supplied as a Welch Allyn / Hillrom ECG and spirometry accessory within medical device regulatory frameworks applicable to the parent systems (e.g. EU MDR / UK MDR, FDA and other national regulations).
  • Listed by major medical distributors under standard medical device accessory codes (e.g. UNSPSC 42271645 or similar cardiopulmonary accessory categories).
  • Latex Free labelling in distributor catalogues to support allergy Risk management in clinical use.
Spirometry and ECG pressure tubing for CardioPerfect Workstation (CPWS) and CP 200

Description

Welch Allyn Pressure Tubing for CardioPerfect Workstation and CP 200 (part number 703415) is a 2.0 m (6.6 ft) length of diagnostic pressure tubing designed specifically for use with Welch Allyn CardioPerfect Workstation (CPWS) and CP 200 electrocardiograph / spirometry systems. It connects the Welch Allyn spirometry flow transducer or related pressure-sensing accessories to the CardioPerfect or CP 200 base unit, enabling accurate transmission of pressure and flow signals during spirometry or cardiopulmonary testing. The tubing is supplied as a single, latex-free, medical-grade accessory with a 2 mm male connector configuration specified for CPWS / CP 200 devices.

Bnefits

  • Designed specifically for Welch Allyn CardioPerfect Workstation (CPWS) and CP 200 electrocardiograph / spirometry systems, ensuring correct fit and performance.
  • Standardised 2.0 m (6.6 ft) length provides adequate reach from patient to device while minimising signal distortion.
  • Precision pressure pathway supports accurate transmission of flow and pressure signals from Welch Allyn spirometry accessories to the workstation.
  • Latex-free construction reduces the risk of latex-related allergic reactions for patients and clinicians.
  • Dedicated 2 mm male connector specification for CPWS / CP 200 simplifies installation and reduces risk of mis-connection.
  • Single-piece replacement accessory helps restore system integrity when original tubing becomes worn, damaged or contaminated.
  • Supplied by multiple reputable medical distributors for easy replacement and servicing.
  • Simple design with smooth internal bore is easy to visually inspect for kinking or damage.

Indications

  • Use as replacement pressure tubing for Welch Allyn CardioPerfect Workstation (CPWS) spirometry configurations.
  • Use as replacement pressure tubing for Welch Allyn CP 200 electrocardiograph with spirometry option.
  • Restoration of proper pressure signal path where the original tubing is damaged, kinked, contaminated or past recommended service life.
  • Support for routine spirometry and cardiopulmonary testing in hospitals, clinics, GP practices and occupational health environments using compatible Welch Allyn systems.

Composition

  • Latex-free medical-grade polymer tubing (e.g. flexible PVC or similar pressure-rated material) suitable for respiratory pressure applications.
  • Integrated 2 mm male connector configuration compatible with CPWS / CP 200 devices.
  • Smooth internal lumen designed for low-resistance pressure and flow transmission.

Formulation

  • Single-lumen flexible pressure tubing, 2.0 m (6.6 ft) nominal length.
  • Configured for Welch Allyn CardioPerfect Workstation and CP 200 electrocardiograph / spirometry systems (CPWS, CP200, 2M).
  • Latex-free, non-sterile accessory intended for multiple-use in accordance with local cleaning and maintenance procedures.
  • Medical device accessory classified as ECG / spirometry accessory within Welch Allyn / Hillrom product lines.

Packaging

  • Supplied as one (1) length of pressure tubing per pack.
  • Typically individually packaged in a labelled bag or pouch identifying part number 703415, product description and manufacturer.
  • Distributed in outer cartons containing multiple individually packaged units for institutional orders.

Usage

  • Use only with compatible Welch Allyn CardioPerfect Workstation (CPWS) and CP 200 electrocardiograph / spirometry systems, following the system operator’s manual.
  • Before use, visually inspect tubing for cracks, discoloration, kinks, occlusions or connector damage; do not use if any defect is observed.
  • Connect the 2 mm male end of the tubing firmly to the specified pressure / spirometry port on the CPWS or CP 200 device as indicated in the system manual.
  • Connect the opposite end to the appropriate Welch Allyn spirometry flow transducer or pressure-sensing accessory, ensuring a secure, leak-free fit.
  • Verify that the tubing is routed without sharp bends or kinks and is not under tension that could pull on connectors during patient testing.
  • Perform any required leak or calibration checks (such as syringe calibration for spirometry) as recommended by Welch Allyn before clinical use.
  • After each patient, clean and disinfect the external surfaces of the tubing in accordance with the device manual and local infection-control policy; do not expose tubing to chemicals or temperatures outside the manufacturer’s recommendations.
  • Replace the tubing immediately if it becomes damaged, heavily soiled, difficult to clean, discoloured or fails any functional checks.
  • Do not attempt to modify, shorten or extend the tubing; use only the specified 2 m length and original connectors to ensure correct performance.

Contraindications

  • Do not use with non-compatible diagnostic systems or devices that are not specified for this tubing type.
  • Do not use if the tubing or connectors appear cracked, brittle, kinked, discoloured or otherwise damaged.
  • Do not use in patients or environments requiring sterile single-use disposable pressure lines unless local policy explicitly permits and the tubing has been appropriately processed.
  • Do not use where latex contact must be absolutely excluded unless the latex-free status of all patient-contact components in the system configuration has been confirmed.
  • Do not use with gases, pressures or chemicals outside the operating limits of the associated Welch Allyn CPWS / CP 200 systems.

Adverse Effects

  • If tubing becomes kinked, occluded or disconnected during testing, inaccurate pressure or flow readings may occur, potentially affecting interpretation of spirometry or cardiopulmonary results.
  • If cleaning and disinfection are not performed correctly between patients, there is a potential risk of cross-contamination via associated patient-contact components (e.g. mouthpieces, flow transducers).
  • Improper routing may create a trip hazard or mechanical strain on connectors, potentially leading to equipment damage or sudden loss of signal.

Storage Conditions

  • Store in a clean, dry environment at room temperature, away from direct sunlight and heat sources.
  • Avoid contact with oils, solvents or harsh chemicals that could degrade the tubing material.
  • Do not store under heavy objects or in tightly bent configurations that could lead to permanent kinks.
  • Keep in original packaging until first use to protect from dust and mechanical damage.
  • Follow any additional storage and handling recommendations provided in the Welch Allyn / Hillrom device or accessory documentation.

Duration

Not applicable; this product is an equipment accessory. The useful service life depends on frequency of use, cleaning / disinfection practices and local maintenance policies. Tubing should be replaced whenever it shows signs of wear, damage or functional degradation.

Onset

Not applicable in the clinical sense; correct function is immediate once the tubing is properly installed, leak-free and the system is calibrated according to the device instructions.

Browse more Diagnostic cardiology / respiratory equipment accessory

ELI 150c Resting Electrocardiograph

ELI 150c Resting Electrocardiograph

Medisave

ELI 150c Resting Electrocardiograph

Medical and Aesthetic Equipment
  • £4,822.79
  • £4,078.79
  • 5 more

MicroTymp3 Tips - 4 Extra Small (7 mm) for Welch Allyn otoscopes

MicroTymp3 Tips - 4 Extra Small (7 mm) for Welch Allyn otoscopes

Medisave

MicroTymp3 Tips - 4 Extra Small (7 mm) for Welch Allyn otoscopes

Medical and Aesthetic Equipment
  • £25.99
  • £28.99
  • 7 more

ELI150c Resting Electrocardiograph with Wireless Patient Cable Module (WAM), Ethernet LAN, XML & PDF, UK Plug

ELI150c Resting Electrocardiograph with Wireless Patient Cable Module (WAM), Ethernet LAN, XML & PDF, UK Plug

Medisave

ELI150c Resting Electrocardiograph with Wireless Patient Cable Module (WAM), Ethernet LAN, XML & PDF, UK Plug

Medical and Aesthetic Equipment
  • £3,091.19
  • £2,762.39
  • 3 more

Welch Allyn Connex Spot Monitor with SureBP Non-Invasive Blood Pressure, Covidien SpO2 and Braun ThermoScan PRO 6000 Thermometry – Plug 4

Welch Allyn Connex Spot Monitor with SureBP Non-Invasive Blood Pressure, Covidien SpO2 and Braun ThermoScan PRO 6000 Thermometry \u2013 Plug 4

Medisave

Welch Allyn Connex Spot Monitor with SureBP Non-Invasive Blood Pressure, Covidien SpO2 and Braun ThermoScan PRO 6000 Thermometry – Plug 4

Medical and Aesthetic Equipment
  • £736.79
  • £571.19
  • 3 more

Welch Allyn Comfort Sealing Eartips (Large, one pair)

Welch Allyn Comfort Sealing Eartips (Large, one pair)

Medisave

Welch Allyn Comfort Sealing Eartips (Large, one pair)

Medical and Aesthetic Equipment
  • £5.49
  • £35.99
  • 2 more

Miller 00 Fiber Optic Laryngoscope Blade

Miller 00 Fiber Optic Laryngoscope Blade

Medisave

Miller 00 Fiber Optic Laryngoscope Blade

Medical and Aesthetic Equipment
  • £206.39
  • £206.39
  • 2 more

ProBP™ 2000 Digital Blood Pressure Device with Power Supply - CLEARANCE

ProBP\u2122 2000 Digital Blood Pressure Device with Power Supply - CLEARANCE

Medisave

ProBP™ 2000 Digital Blood Pressure Device with Power Supply - CLEARANCE

Medical and Aesthetic Equipment
  • £87.59
  • £257.99
  • 2 more

GS777 Integrated Wall System, PanOptic, MacroView for CSM UK

GS777 Integrated Wall System, PanOptic, MacroView for CSM UK

Medisave

GS777 Integrated Wall System, PanOptic, MacroView for CSM UK

Medical and Aesthetic Equipment
  • £2,279.99
  • £2,243.99
  • 0 more

Welch Allyn SureBP Double-Tube Blood Pressure Hose, 10 ft (3.0 m)

Welch Allyn SureBP Double-Tube Blood Pressure Hose, 10 ft (3.0 m)

Medisave

Welch Allyn SureBP Double-Tube Blood Pressure Hose, 10 ft (3.0 m)

Medical and Aesthetic Equipment
  • £80.39
  • £64.79
  • 1 more

ELI 230 Resting Electrocardiograph with Wireless Patient Cable Module (WAM), UK Plug

ELI 230 Resting Electrocardiograph with Wireless Patient Cable Module (WAM), UK Plug

Medisave

ELI 230 Resting Electrocardiograph with Wireless Patient Cable Module (WAM), UK Plug

Medical and Aesthetic Equipment
  • £1,689.59
  • £1,919.99
  • 0 more

ProBP 2400 Blood Pressure Cuff, Large Adult Long (32 - 52cm)

ProBP 2400 Blood Pressure Cuff, Large Adult Long (32 - 52cm)

Medisave

ProBP 2400 Blood Pressure Cuff, Large Adult Long (32 - 52cm)

Medical and Aesthetic Equipment
  • £46.79
  • £56.39
  • 1 more

ECG Thermal Z-Fold to Use With ELI150/150C - 1 Pack of 200 Sheets

ECG Thermal Z-Fold to Use With ELI150/150C - 1 Pack of 200 Sheets

Medisave

ECG Thermal Z-Fold to Use With ELI150/150C - 1 Pack of 200 Sheets

Medical and Aesthetic Equipment
  • £32.39
  • £14.39
  • 1 more